Page 3 of 5
Route: I-80
Place: San Francisco
Facility Carried: W80-FREMONT ST OFF
Feature Intersected: STERLING-E80,BRYANT,RNCN
Location: 04-SF-080-5.45-SF
Bridge Material and Design: Concrete continuous Tee Beam
Sufficiency Rating: 56.8 %
Structural Evaluation: Meets minimum tolerable limits to be left in place as is
Structure Length: 315.5 meters
Year Built: 1935
Year Reconstructed: 1961
NBI Structure Number: ++++++34+0117S
This bridge is Structurally Deficient
Route: U.S. 101
Place: San Francisco
Facility Carried: I 280 - 101S (WU)
Feature Intersected: 280/101 INTERCHANGE
Location: 04-SF-101-1.48-SF
Bridge Material and Design: Concrete continuous Box Beam or Girders - Multiple
Sufficiency Rating: 62 %
Structural Evaluation: Somewhat better than minimum adequacy to tolerate being left in place as is
Structure Length: 274.9 meters
Year Built: 1960
NBI Structure Number: ++++++34+0070H
This bridge is Structurally Deficient
Route: 1
Place: San Francisco
Facility Carried: STATE ROUTE 1
Feature Intersected: KOBBE AVE
Location: 04-SF-001-6.67-SF
Bridge Material and Design: Concrete continuous Tee Beam
Sufficiency Rating: 58.3 %
Structural Evaluation: Equal to present minimum criteria
Structure Length: 215.8 meters
Year Built: 1939
NBI Structure Number: ++++++34+0017
This bridge is Structurally Deficient
Route: U.S. 101
Place: San Francisco
Facility Carried: U.S. HIGHWAY 101
Feature Intersected: CESAR CHAVEZ BLVD
Location: 04-SF-101-2.92-SF
Bridge Material and Design: Steel Stringer/Multi-beam or Girder
Sufficiency Rating: 91 %
Structural Evaluation: Equal to present minimum criteria
Structure Length: 190.5 meters
Year Built: 1951
Year Reconstructed: 1968
NBI Structure Number: ++++++34+0034
This bridge is Structurally Deficient
Route: I-280
Place: San Francisco
Facility Carried: I280S OFF-MONTEREY
Feature Intersected: I 280,SAN JOSE,MUNI,BART
Location: 04-SF-280-R2.72-SF
Bridge Material and Design: Concrete continuous Box Beam or Girders - Multiple
Sufficiency Rating: 87.8 %
Structural Evaluation: Better than present minimum criteria
Structure Length: 169.8 meters
Year Built: 1964
NBI Structure Number: ++++++34+0079K
This bridge is Structurally Deficient
Route: I-280
Place: San Francisco
Facility Carried: I 280N (RE, AL)
Feature Intersected: 101/280 INTERCHANGE
Location: 04-SF-280-R4.07-SF
Bridge Material and Design: Concrete continuous Box Beam or Girders - Multiple
Sufficiency Rating: 77 %
Structural Evaluation: Equal to present minimum criteria
Structure Length: 150.6 meters
Year Built: 1960
NBI Structure Number: ++++++34+0133R
This bridge is Structurally Deficient
Route: D008
Place: San Francisco
Facility Carried: BAYSHORE BLVD
Feature Intersected: ROUTE 101
Location: 04-SF-101-.56-SF
Bridge Material and Design: Steel Stringer/Multi-beam or Girder
Sufficiency Rating: 61 %
Structural Evaluation: Somewhat better than minimum adequacy to tolerate being left in place as is
Structure Length: 148.7 meters
Year Built: 1970
NBI Structure Number: ++++++34+0103
This bridge is Structurally Deficient